LG Refrigerators

Error Code CO E

Communication Error (Main PCB to Display PCB)

Moderate

Address soon - your appliance may not work properly

Also displayed as: CO E

How to Fix

  1. 1

    Check all connectors for loose connection; reseat harnesses at hinge connection points.

  2. 2

    Measure voltage at CON101 pins 7–6: expected 12V. If not 12V, replace Main PCB.

  3. 3

    Measure voltage at CON101 pins 3–6: expected 5V. If not 5V, replace Main PCB.

  4. 4

    Measure voltage at CON101 pins 5–6: expected not 0V and not 5V (active communication). If reading is 0V or 5V static, replace Display PCB.

  5. 5

    Measure voltage at CON101 pins 4–6: expected not 0V and not 5V. If static, replace Main PCB.

  6. 6

    Measure voltage at CON6 pins 8–9: expected not 0V and not 5V. If static, replace Display PCB.

  7. 7

    Measure voltage at CON6 pins 10–9: expected not 0V and not 5V. If static, replace Main PCB.

  8. 8

    If all communication voltages are in range: explain to customer.

This Error Applies To

LG LRFS28XB Series Refrigerators

Service manual exact match: LRFS28XBD/00Service manual exact match: LRFS28XBS/00Service manual exact match: LRFS28XBM/01